CNC router machine problem analysis
CNC router engraver cutting machine problem analysis
◆ uniaxial or triaxial engraving machine does not move around or walking is not normal1 Control Carcassonne action or failure ; 2 drive failures corresponding axis ; 3 -axis stepper motor corresponding fault ; 4 corresponding coupling broken out or loose ( loose coupling manifestations , carving font dislocation ) ; 5 corresponding screw nut screw breakage or malfunction ; 6 -axis corresponds to the fast sliding failure ; 7 drives segments, current, and the software is not set up the same.
◆ CNC router machine z -axis control ( bar knife )
1 Control Carcassonne action or failure ; 2 static ; 3.z axis motor line failure ; 4 file path is incorrect ; 5 inverter interference ; 6 computer system problems or a virus ; 7.Z axis motor power enough, loose coupling ; 8.Z shaft drive current is too small , or signal lines are wrong .
◆ CNC router machine error
1 controls are loose or fault ; 2 drive failures ; .. 3 stepper motor failure ; 4 static ; 5 motor line failure ; 6 data line failure ; .. 7 path is wrong ; 8 coupling breakage or loose ; 9 processing speed is too fast ; ( system parameter curve acceleration is too large ) 10 computer system problem or a virus ) .
◆ CNC router machine engraving shades
1 Control Carcassonne action or failure ; 2 stepper motor failure ; 3 drive failure or software settings are inconsistent with the current subdivision ; 4.z axis motor line failure ; 5 spindle motor failure ; 6 inverter interference or data set . wrong ; 7 static ; 8 computer virus or system problems ; 9 working platform uneven .
◆ CNC router machine carve
1 controller card failure ; 2 inverter interference ; 3 file path is incorrect ; 4 static ; 5 software provided with the problem ; 6 drive failure or current breakdown is set incorrectly ; 7 data line failure ; 8 computer virus or system problems.
◆ CNC router machine milling end injustice
1 vertical spindle and the table does not need correction ( presenting symptoms : the knife and sword of the shades ) ; 2 knives in question ; 3 control card problems ; 4.Z axis Z -axis screw drive or have a problem ...
◆ engraving machine spindle stop
1 spindle internal short circuit ; 2 current shield ; 3 inverter parameter settings are incorrect or own fault ; 4 controller card failure ; 5 main axis or data line shorted.
◆ CNC router machine spindle rotation does not sound normal
1 inverter is set incorrectly ; 2 spindle does not turn ; 3 spindle itself has a problem ( bearing damage ) .
Conversely when walking or engraving machine ◆ Homing direction
1 change in Notepad document ; 2 wiring methods to modify the inverter ; 3 modify the motor direction Weihong software.
◆ CNC engraving machine machine not working Homing
1 in the opposite direction ; 2 controller card failure or loose ; 3 limit switches or data line failure ; 4 drive failure ; . Nearly five-step motor failure .
◆ CNC router machine spindle automatic transfer or can not stop
1 controller card failure ; 2 drive failures.
◆ CNC router machine when opened Weihong software, computer Tip "Operation failed"
1 Check the board driver has not installed , or the board for a PCI slot ; 2 to reinstall the two data cables , check there is no breakage phenomenon ; 3 boards have problems, replace board .
◆ CNC router machine when you open the software prompts : triaxial alarm, initialization errors IV
1 Check the computer and the machine two data lines are not connected well ; . 2 Check the control box adapter plate fuse is burned , replace the fuse ; . 3 Check 85V power supply is normal .
When dislocation occurs or the wrong size ◆ engraving machine engraving
1 Check the correctness of the path engraving software ; 2 inspection screw fastening screw and rod gap size has no loose ; 3 Check the software parameters set correctly .
◆ CNC router machine X -axis Z -axis is not certain when walking carrying knives , according to go up but go down
1 Check the Z -axis stepper motor is running, the current size of the power and drive or own fault ; . 2 Check the Z -axis stepper motor cable is bad or intermittent cases ; 3 controller card failure.